RadPro with Canon 55C Panel

Manufacturer: Canon
Price: 65000,00 $

RadPro 40kW Mobile Digital X-Ray System with Canon 55C Digital Panel

§ Battery Assisted High Frequency generator
§ Microprocessor Controlled
§ Auto diagnostic System for easy maintenance.
§ Tube overload protection continuously Monitoring of the remaining X-Ray Tube Heat Units
§ Anatomical Programmer APR with more than 500 program capability.
§ Automatic selection of the radiographic parameters programmed (kVp., mA, time or mAs and focal spot, according with patient size and anatomical area selected).
§ Power 40 kW. According to IEC
§ KVp Range from 40 KVp to 150 KVp in 1 KVp Steps.
§ mA range from 10 to 500 mA in Renard scale: 10, 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160, 200, 250, 320, 400, 500 mA
§ mAs Range 0.1 to 500 mAs.
§ Time range from 1 ms. to 8 sec. 40 Time stations. Renard Scale
§ User Friendly Touch Control Panel with Digital Displays for KVp, mAs, mA and time.
§ Two and three points console.
§ Two point console KVp and mAs selection only.
§ Three point console KVp, mA and time selection.
§ Two step Hand switch for preparation and exposure.
§ Audible and light indication for x-ray exposure.
§ Line requirement: 110/230 VAC single phase ±10%
§ 300 KHU, 0.6 - 1.2 Focal Spot Tube Upgrade for RadPro Mobile X-Ray Systems
TUBE STAND COLUMN MOBILE UNIT:
§ Motorized Unit. 4 km/h Speed. Pressure Sensitive Moving System (Patent).
§ Two Independent Motors one for each wheel. Forward and Backward movement.
§ Excellent mobility with large rear wheels for easy transportation even over small obstacles.
§ Independent Battery Charge Indicators for Driving and Generator Batteries.
§ Anti Collision System. Frontal and Lateral.
§ Easy access to any elevator, hall-way, doors and patient bed side.
§ Quick and sturdy breaking system control when operator releases the handle.
§ Manual rotary collimator with x-ray covers area light indication.
§ Possibility of Lighting the Collimator from booth Collimator and Front Panel.
§ Ergonomic touch control panel with sensitive push button.
§ Emergency Stop push button, clearly accessible.
§ Tube stand column rotation +/- 270º
§ Tube rotation "X" axis +/- 155º
§ Tube rotation "Z" axis 90º
§ Vertical tube travel 145 cm.
§ Horizontal tube travel 60 cm.
§ Counterbalanced tube arm.
§ Electromagnetic breaks with release from the Collimator and Front Handle
§ Maximum Focal Distance 202.5 cm to the floor
§ Minimum Focal Distance 57.5 cm to the floor.
§ Computer: High performance control unit with wireless data communications
§ Designed to withstand sever shock and continual vibration, making them ideal for use in a portable environment.

 



Contact Us

Accessories Catalog

Browse Online | PDF | Order