RadPro w/ Canon RD NO PANEL

Manufacturer: Canon
Price: 15000,00 $

RadPro 40kW Mobile Digital X-Ray System with NO digtial panel.  This system was previously configured with a Canon 50C panel.  The interface box for the panel and Canon PC with CXDI RD remain with system.  Just add a panel and you will have a fully working DR portable.

§ Battery Assisted High Frequency generator 
§ Microprocessor Controlled 
§ Auto diagnostic System for easy maintenance. 
§ Tube overload protection continuously Monitoring of the remaining X-Ray Tube Heat Units 
§ Anatomical Programmer APR with more than 500 program capability. 
§ Automatic selection of the radiographic parameters programmed (kVp., mA, time or mAs and focal spot, according with patient size and anatomical area selected). 
§ Power 40 kW. According to IEC 
§ KVp Range from 40 KVp to 150 KVp in 1 KVp Steps. 
§ mA range from 10 to 500 mA in Renard scale: 10, 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160, 200, 250, 320, 400, 500 mA 
§ mAs Range 0.1 to 500 mAs. 
§ Time range from 1 ms. to 8 sec. 40 Time stations. Renard Scale 
§ User Friendly Touch Control Panel with Digital Displays for KVp, mAs, mA and time. 
§ Two and three points console. 
§ Two point console KVp and mAs selection only. 
§ Three point console KVp, mA and time selection. 
§ Two step Hand switch for preparation and exposure. 
§ Audible and light indication for x-ray exposure. 
§ Line requirement: 110/230 VAC single phase ±10% 
§ 300 KHU, 0.6 - 1.2 Focal Spot Tube Upgrade for RadPro Mobile X-Ray Systems 
TUBE STAND COLUMN MOBILE UNIT: 
§ Motorized Unit. 4 km/h Speed. Pressure Sensitive Moving System (Patent). 
§ Two Independent Motors one for each wheel. Forward and Backward movement. 
§ Excellent mobility with large rear wheels for easy transportation even over small obstacles. 
§ Independent Battery Charge Indicators for Driving and Generator Batteries. 
§ Anti Collision System. Frontal and Lateral. 
§ Easy access to any elevator, hall-way, doors and patient bed side. 
§ Quick and sturdy breaking system control when operator releases the handle. 
§ Manual rotary collimator with x-ray covers area light indication. 
§ Possibility of Lighting the Collimator from booth Collimator and Front Panel. 
§ Ergonomic touch control panel with sensitive push button. 
§ Emergency Stop push button, clearly accessible. 
§ Tube stand column rotation +/- 270º 
§ Tube rotation "X" axis +/- 155º 
§ Tube rotation "Z" axis 90º 
§ Vertical tube travel 145 cm. 
§ Horizontal tube travel 60 cm. 
§ Counterbalanced tube arm. 
§ Electromagnetic breaks with release from the Collimator and Front Handle 
§ Maximum Focal Distance 202.5 cm to the floor 
§ Minimum Focal Distance 57.5 cm to the floor. 
§ Computer: High performance control unit with wireless data communications 
§ Designed to withstand sever shock and continual vibration, making them ideal for use in a portable environment. 

 



Contact Us

Accessories Catalog

Browse Online | PDF | Order